Principle of the detector


large number of small diameter scintillating fibres and highly integrated readout through optoelectronic devices (e.g. 5 x 10^5 capillaries of 20 micron inner diameter are read out by a single image intensifier chain of 40 mm input window)

SCIFI DETECTORS can be built using glass fibres, plastic fibres or glass capillaries filled with liquid scintillator

Why Capillaries ?

fast response (as for plastic fibres)
high reflectivity of core-cladding interface (light loss per reflection ~10^-6)
attenuation length (>~3 m) even in thin fibres
high spatial resolution} related to the small fibre diameter and the readout resolution
radiation hardness > 100 Mrad
high hit density allowing the reconstruction of track vectors in thin capillary layers